Description
The MVE-2-RS Network HVAC Actuator is a multiprotocol, high-precision linear actuator designed for PICV and globe valves in advanced hydronic applications. It integrates energy monitoring and temperature control capabilities, enabling ΔT optimization, power limitation and full thermal energy calculation when used with compatible sensors.
With support for BACnet MS/TP, Modbus RTU and analog control, the actuator fits seamlessly into any BMS environment, while its automatic stroke calibration ensures consistently accurate valve positioning.
Available in 24 V or 230 V versions, and with an optional emergency fail-safe return based on supercapacitor technology, MVE-2-RS ensures safe operation even during power outages. The long-stroke version provides full stem travel for maximum valve compatibility, including PICVs and large globe valves.
Its robust housing, RS-485 connectivity, USB diagnostic port and integrated self-diagnostic features make MVE-2-RS a powerful platform for coils, district-energy interfaces and custom Energy Valve configurations.
Key Features
Network actuator with BACnet MS/TP and Modbus RTU connectivity.
Supports ΔT optimization, power limitation, energy calculation and temperature control.
BLDC linear drive with automatic stroke calibration.
Long-stroke version for valves requiring extended stem travel.
Stroke capability up to 20–30 mm (depending on valve model).
Force range up to 1500 N, suitable for a broad valve portfolio.
Compatible with PICV and globe valves from DN15…DN80.
USB interface for configuration, diagnostics and firmware updates.
Available in 24 V and 230 V supply versions.
Optional Fail-Safe (Emergency Return) version using supercapacitor technology.
Universal U-bolt mounting system for fast installation.
Benefits
One actuator platform for PICV, globe valves and energy control applications.
Full energy-monitoring functionality without external controllers.
Safe operation in critical systems thanks to emergency fail-safe capability.
Flexible installation in BMS architectures using analog or network control.
High positioning accuracy and stable modulation with BLDC drive.
Fast commissioning with auto calibration and intuitive configuration tools.
ApplicationsAHU coils, fan coils and district-heating substations.
Globe valves in hydronic heating and cooling loops.
Custom Energy Valve setups with ΔT and power limitation functions.
Large stroke valve installations requiring wide stem travel.
Applications where fail-safe function is required.